islands incinerators



Application : four islands in Croatia

Capacity/island : 4000 kg/day ; 25000 kg/day ; 31000 kg/day ; 48000 kg/day
Burning temperature – over 12000C
Two chambers – minimum
Emissions – dioxin and heavy metaly – better then Kyoto protocol
Emission – monitoring system
Waste unloiding – directly from waste track to incinerator
Burn Rate(Average kgs/hr)
 25 kg
 
primary chamber
 800 degree
 
secondary chamber
 1000 degree
 
chimney
 standard
 
shredder
 separately
 
Autoclave or microwaves
 separately
 
temperature monitor
 attached outside of machine
operating
 Fuel and electric
 
–          Toxic and dangerous wastes,  
–          Medical pharmaceutical and hospitable liquids  Wastes
–          Domestic garbage  
–          Electric and electronic wastes
–          Industrial wastes
–          In General, all type of wastes and garbages
1) working now in new order for Nigeria though our company for Yd-300 x 2 units , this is a job in hand in our customer located in dubai
2) the customer also want also to buy a fuel bulk storage tank  to be for 3 days continuous operation so we hope also you can manufacture it
so please give me the best price for fuel bulk storage tank  to be for 3 days continuous operation for YD-300
3) installation must be in the site in Nigeria by your company ,as i know your price rate which you sent to be before
4) what is the best price CIF Nigeria in lagos sea port as i have only price for cif dubai
5) 150 pcs Waste Containers (820 L) fully compatible with the incinerator and clinical waste container washing system.  please send me the price and catalog for this item
6) also they need Automatic Clinical Waste Container Washing System complete in every respect and fully compatible with containers price and catalog
7) 2 units 1.5 tonne Fork Lift  ( if you know good price and quality  company in china)
8) 1 unit Clinical Waste Container Vehicles complete in every respect and fully compatible with containers.
9) Spare Parts For 2 Years Operation & Maintenance  for YD-300 and for the above machines
10) all parts , pipe work electrical work and civil work for incinerator must be provided and material must be quoted
The highest temperature that the filter bag can operate continuously is 260C.    In order to add a bag house using our filter products, 
you would need to add a water cooling tower or other method to reduce the inlet temperature at the baghouse to less than 260C.   
If you cannot lower the temperature below 260C, then we cannot utilize our membrane filter bags.  

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]

Posted in English | Tagged , , , , , , , , , , , , ,