and forced air exhaust stacks (or chimneys).
The charging system shall consist of, as a minimum, a hopper for top feeding and mechanically operated hydraulic
charging ram or augur. To prevent warpage or excessive thermal expansion, a charger cooling system using either
air or water shall be provided.
Primary combustion chamber shall be either the rotary- or stationary fixed-hearth (or kiln) type incinerator. Burner
and combustion air controls shall be fully automatic comprising of, as a minimum, electronic ignition and all
necessary interlocks and safety devices to provide safe operation. The chamber and burner shall be designed to
maintain a minimum combustion temperature of at least 700 to 870 C (1300 to 1600 F), but shall not to exceed 980
C (1800 F). The ash-removal system shall consist of the automatic continuous removal of the ash into an ashquench
pit where cooled by water and removed by conveyor.
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]