pet cremation incinerator cost



Intermittent Feed (w/optional loader): .9 yd3/hr (.7 m3/hr) up to 8 hrs/day

 

 

 

 

Specifications: Length overall -9′-6″ (2896 mm) batch system w/o loader

 

 

 

 

18′-6″ (5639mm) w/optional loader system Width overall -7′-6″ (2820mm)

 

 

 

 

Height (w/o stack) -10′-0″ (3048mm) Approx. Weight – 14,000 lbs. (6364 kg) w/o

 

 

 

 

Loader

 

 

  1. The average dioxin and furan concentration in the emissions should not exceed 80ng/m3 total dioxins and furans

if measured for a period of 6 to 16 hours.

 

Note:

All pollutant concentrations must be expressed at Oo C and 1.013 x 10 5 N/m2, dry gas and 11% oxygen correction.

 

Oxygen correction is computed as:

 

Es =      21 – Os    x EM

21 – OM

 

Where:   Es   = Calculated emission concentration at the standard percentage oxygen concentration

EM = Measured emission concentration

Os   = Standard oxygen concentration

OM = measured oxygen concentration

 

10   Operation     1.    Materials destined for incineration should be of known origin and composition and must

be only incinerated in a furnace that is registered for the particular type of waste.

 

  1. A record must be kept of the quantity, type and origin of the waste to be incinerated.
  2. The incinerator must be preheated to working temperature before charging any waste.
  3. The incinerator must not be overcharged.
  4. The incinerator must be in good working order at all times and must not be used if any component fails. Any

malfunction should be recorded in a log book and reported to the relevant authority.

 

  1. The incinerator operator and all relevant staff must be trained to the satisfaction of the relevant control

authority.

 

11   Housekeeping     The site where the incinerator is built must:

 

  1. Have running water.
  2. Have a solid floor.
  3. Have lighting if 24hrs operation
  4. Have fly ash containerization and storage before disposal.

 

 

12   Health & Safety (Protective Gear) 1.    Staff handling waste must be well trained on safe handling of

hazardous wastes

  1. Staff must be provided with appropriate protective gear such as, gas mask, aprons, gumboots, helmets, gloves,

goggles.

 

  1. Caution and Warning signs must be provided.
  2. Fire fighting equipment must be provided
  3. There should be no smoking or eating on the site.

 

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]